Livestock ventilation

Built around the continuous-duty needs of livestock ventilation.

Equipment
Negative-pressure axial fan · up to 58 in
Model conclusion
Pending airflow and static-pressure selection
Control
Continuous speed · RS485 / 0–10 V
Key concern
Low-speed torque · continuous duty · noise

Measured data availableC

Built around the continuous-duty needs of livestock ventilation.

Livestock housing ventilation is a continuous load: airflow follows house temperature and stocking density, changing operating point many times a day. A fixed-frequency induction scheme commonly approximates demand by switching units, while an integrated EC system can provide continuous speed control. Usable low-speed torque and continuous-duty range still require controller and thermal-limit confirmation.

Existing equipment photo · negative-pressure axial fan
Existing equipment photo · negative-pressure axial fan
D-02Duty parameters

Key duty parameters

Of the available Rasta material, only this application retains four test points. The sample table shows airflow falling and tabulated power rising as static pressure increases. It records this test and is not a universal rule for every fan or product.

Equipment
Negative-pressure axial fan · up to 58 in
Model conclusion
Pending airflow and static-pressure selection
Control
Continuous speed · RS485 / 0–10 V
Key concern
Low-speed torque · continuous duty · noise
D-03Measured results

58-inch fan, four static-pressure points

Effect of static pressure on airflow and efficiency3-phase 380 VAC · 2.2 kW · 750 rpm
0k20k40k60k80k01530450507510071,63542,144m³/h(m³/h)/WStatic pressure Pa
Airflow m³/hEfficiency (m³/h)/W
Static ParpmFlow m³/hPower WEff.
074671,6351,73041.17
5074660,4442,36025.56
7574550,8652,60019.37
10074542,1442,75015.24

Unit correction

The source labels the power column kW. Airflow divided by power gives about 41.41 / 25.61 / 19.56 / 15.33, close in magnitude to the tabulated 41.17 / 25.56 / 19.37 / 15.24. This supports W as the likely unit but is not an exact match; the original unit and calculation basis require written factory confirmation before publication.

The sample is not the recommendation

The 2.2 kW / 750 rpm motor is the validation sample and sits in the EC80 power band. It records this negative-pressure test only and is not the selection answer for a 58-inch fan; the actual model must be selected against airflow, static pressure, impeller and installation conditions.

Equipment: 58-inch livestock negative-pressure axial fan; motor: 3-phase 380 VAC · 2.2 kW · 750 rpm. The source table comes from the legacy axial-fan page, re-checked 2026-09-19 with values unchanged. Instrument, test conditions, report date and sample information are pending.

D-04Recommended models

Confirm the suitable model against the actual duty

The available material does not establish a verifiable match between a 58-inch fan duty point and any specific model, so neither EC100 nor EC112 is recommended yet. Selection requires the target duty point, impeller data, minimum speed and mounting form.

Submit duty details for selection support