Skip to content

EC80 series

Two market versions in the EC80 product series with the same power band. For compact, low-power ventilation equipment needing local speed control.

Product series
EC80
Versions
2
Power
0.375 – 2.2 kW
Speed
500–1500 rpm
S-01EC80 · Series overview

EC80 series overview

Two market versions in the EC80 product series with the same power band. For compact, low-power ventilation equipment needing local speed control.

Supply
1 / 3-phase 220 VAC; 3-phase 380 VAC, ±10%
Control interface
RS485 · 0–10 V speed reference
Ambient
−20 … 40 °C
Frequency
50 / 60 Hz

Protections

Legacy listing: phase loss · locked rotor · surge · over/under voltage · overcurrent · temperature (confirm by controller revision)

CLegacy claim; must be verified against the actual controller revision

EC80 domestic version motor, studio product photo
Domestic
EC80 overseas version motor, studio product photo
Overseas
S-02.1EC80 · Domestic

The most compact product series

Motor and control share one housing — for equipment with tight mounting space that still needs local speed control. EC80 is the most compact of the three product series, covering 0.375 to 2.2 kW.

What sets this version apart

Built to domestic wiring and selection conventions. It shares the EC80 product series and power band with the overseas version; differences lie in wiring and documentation, confirmed per order.

Rated power
0.375 – 2.2 kWB
Speed range
500 – 1500 rpmB
Rated torque
To confirmD
Product seriesEC80B
Rated power0.375 – 2.2 kWB
Speed range500 – 1500 rpmB
Rated torqueTo confirmDThe available material gives power and speed ranges, not paired operating points; range extremes cannot be combined into rated torque
Supply1 / 3-phase 220 VAC; 3-phase 380 VAC, ±10%B
Frequency50 / 60 HzB
CoolingTotally enclosed, integratedB
Power factorTo confirmDThree different ranges across the legacy pages with no measurement condition stated; version and operating point required
MountingTo confirmDThe overview list does not match the coverage of the spec drawings; engineering drawings must govern
Overall length mmTo confirmDThe Chinese drawing reads 230 / 280 mm while both English sources read 290 / 340 mm — a direct conflict
Control interfaceRS485 · 0–10 V speed referenceB
Ambient temperature−20 … 40 °CB
Efficiency classTo confirmDAll five versions claim IE5; no test report locally, withheld
ProtectionTo confirmDNo test evidence; ISO 9001 is a system certificate, not an IP test
Insulation classEC80 legacy FAQ: Class F · 155 °C · highest 98 °C on 2.2 kW (test conditions pending)C

Fields shown as “to confirm” are conflicting, lack an applicable scope or lack paired operating points, and are not confirmed specifications.

Torque awaits paired operating points

T = 9550·P/n converts one paired operating point. The available material gives power and speed as ranges, so maximum power cannot be combined with minimum speed as rated torque. The real envelope waits for continuous/peak torque, base speed, controller and thermal limits.

Placeholder
EC80 Domestic outline and mounting drawing

Needs an engineering drawing carrying a revision date and drawing number: product outline, shaft diameter and length, flange spec, foot-hole positions. No drawing exists locally — the second item blocking sign-off of the product pages.

S-02.2EC80 · Overseas

EC80 for export markets

It shares the EC80 product series and power band with the domestic version, adapted to export wiring and selection conventions. The legacy page additionally claims a higher power factor and CE compliance — both need documentation.

What sets this version apart

This is the only version carrying extra claims on the legacy site — higher power factor and CE compliance. That is exactly why both need a declaration on file before they can be stated publicly.

Rated power
0.375 – 2.2 kWB
Speed range
500 – 1500 rpmB
Rated torque
To confirmD
Product seriesEC80B
Rated power0.375 – 2.2 kWB
Speed range500 – 1500 rpmB
Rated torqueTo confirmDThe available material gives power and speed ranges, not paired operating points; range extremes cannot be combined into rated torque
Supply1 / 3-phase 220 VAC; 3-phase 380 VAC, ±10%B
Frequency50 / 60 HzB
CoolingTotally enclosed, integratedB
Power factorTo confirmDA different range from the domestic version in the same EC80 product series, with no measurement condition
MountingTo confirmDOverview and drawings do not fully agree
Overall length mm290 / 340B
Control interfaceRS485 · 0–10 V speed referenceB
Ambient temperature−20 … 40 °CB
Efficiency classTo confirmDAll five versions claim IE5; no test report locally, withheld
ProtectionTo confirmDNo test evidence; ISO 9001 is a system certificate, not an IP test
Insulation classEC80 legacy FAQ: Class F · 155 °C · highest 98 °C on 2.2 kW (test conditions pending)C

Fields shown as “to confirm” are conflicting, lack an applicable scope or lack paired operating points, and are not confirmed specifications.

Torque awaits paired operating points

T = 9550·P/n converts one paired operating point. The available material gives power and speed as ranges, so maximum power cannot be combined with minimum speed as rated torque. The real envelope waits for continuous/peak torque, base speed, controller and thermal limits.

Placeholder
EC80 Overseas outline and mounting drawing

Needs an engineering drawing carrying a revision date and drawing number: product outline, shaft diameter and length, flange spec, foot-hole positions. No drawing exists locally — the second item blocking sign-off of the product pages.

S-03Materials & performance

Materials, construction and performance information

Bearing numbers, silicon steel, magnets, coating — none of these needs a test report to verify, and each can be traced back to a supplier. To a selection engineer this layer says more than an efficiency label with no report behind it.

Materials

  • BearingsFront 6305-2RS / rear 6205-2RSB
  • Bearing brand0.375–1.1 kW: C&U · 1.5–2.2 kW: NSKBSplit by power band, not by version
  • Silicon steel50W470B
  • MagnetNdFeBBStated in the shared product features on all five versions
  • CoatingImported PPG powder coatingBThe coating brand is usable; the legacy claim of 700 hours salt spray has no report and is withdrawn
  • Weight7.6–13 kg across 0.375–2.2 kWB

Insulation: the EC80 legacy FAQ separately states Class F / 155 °C and a highest 98 °C value for the 2.2 kW motor. With conditions and definitions missing, they are not subtracted into a temperature-rise promise.

Performance by operating point

No point-by-point performance data exists locally for this series. Of the five versions only the EC100 TEAO was cached with a full eight points — power, speed, torque, efficiency, full-load current and weight; the rest remain images. This slot waits on an editable specification from the factory.

S-05Documents & enquiry

EC80 technical documents and selection support

  • Product specification, all five versionsPending
  • Dimension drawings (product outline / shaft / flange / foot holes)Pending
  • RS485 register map and 0–10 V mappingPending
  • Efficiency curves (measured at typical operating points)Pending

Specifications, dimensional drawings, wiring diagrams and control protocols are pending factory archiving. Submit the required model and document type for follow-up.